{"product_id":"universal-reload-pipette-tips","title":"Universal Reload Pipette Tips","description":"\u003cp\u003eUniversal reload pipette tips from Sorenson Bioscience: refill inserts for reusable tip racks compatible with most major pipette brands. The reload system reduces plastic waste by reusing rack bases while maintaining the same tip quality as standard racked tips.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal fit reload inserts\u003c\/li\u003e\n\u003cli\u003eCompatible with reusable tip rack bases\u003c\/li\u003e\n\u003cli\u003eAvailable in 10µL, 200µL, and 1250µL sizes\u003c\/li\u003e\n\u003cli\u003eReduces plastic waste and costs\u003c\/li\u003e\n\u003cli\u003eNon-sterile, autoclavable, DNase\/RNase-free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolumes\u003c\/td\u003e\n\u003ctd\u003e10µL, 200µL, 1250µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal fit (reload format)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eReload insert for reusable racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eNon-sterile, autoclavable; DNase\/RNase-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Quantity\u003c\/td\u003e\n\u003ctd\u003e3,840 per case (10 µL, 200 µL); 3,072 per case (1250 µL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePipette compatibility\u003c\/h3\u003e\n\u003cp\u003eReload inserts are universal fit tips for pipettes with a tapered tip cone. The manufacturer's published Tip Compatibility Chart (2016 liquid handling catalog, PDF revised 2024-11-18, retrieved 2026-08-30) lists per-model fitment for its universal fit tip lines across Gilson PIPETMAN, Eppendorf Reference, Research, Research Pro and Research Plus, Rainin Pipet-Plus and EDP, Biohit (now Sartorius) mLine, ProLine, eLine and ePet, Labnet Labpette and Socorex Acura. The chart predates current product names, so it supports the fit of these tip lines rather than certifying any individual catalog number. Request a sample and confirm on your own pipettes, including any multichannels, before a case order.\u003c\/p\u003e\n\u003cp\u003eNot compatible: Rainin LTS pipettes (see our LTS compatible reload tips), INTEGRA GripTip pipettes, and Thermo Finnpipette F1-ClipTip and E1-ClipTip models, which operate only with ClipTip tips (Thermo Scientific F1-ClipTip IFU 1508990-10 and E1-ClipTip user manual 1508890-16, retrieved 2026-08-30).\u003c\/p\u003e\n\u003cstyle\u003e.tc-tablewrap{overflow-x:auto}table.tc-fit{border-collapse:collapse;width:100%;margin:12px 0 16px}table.tc-fit th,table.tc-fit td{border:1px solid #d9e2ea;padding:8px 10px;text-align:left;vertical-align:top;font-size:14px;line-height:1.5}table.tc-fit th{background:#eef3f7;color:#003f63}table.tc-fit td:first-child{white-space:nowrap}.tc-fit-n{font-size:13px;color:#4a5568;font-weight:400}\u003c\/style\u003e\n\u003ch3\u003eFits these pipette models, by size\u003c\/h3\u003e\n\u003cp\u003eThe models below are the ones the manufacturer's published Tip Compatibility Chart (2016 liquid handling catalog) marks for each size of these universal fit reload tips, read model by model on 2026-09-02. A model with no tag is marked single-channel; (MC) means the chart marks it for multichannel use only; (SC\/MC) means either. The chart marks every 1000 µL and 1250 µL size single-channel only. The chart predates current product names and tip cones wear, so confirm on your own instruments before a case order.\u003c\/p\u003e\n\u003cdiv class=\"tc-tablewrap\"\u003e\u003ctable class=\"tc-fit\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003ePipette models marked on the chart\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e10 µL\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"tc-fit-n\"\u003e24 models, 8 with multichannel fit\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eEppendorf\u003c\/strong\u003e Reference 2.5, Reference 10, Research 2.5, Research 10, Research Pro 10 (SC\/MC), Research Plus 10 (SC\/MC); \u003cstrong\u003eGilson\u003c\/strong\u003e Pipetman 10, Pipetman Neo 2, Pipetman Neo 10; \u003cstrong\u003eSartorius\u003c\/strong\u003e mLine 3, mLine 10 (SC\/MC), ProLine 3, ProLine 10 (SC\/MC), ProLine Mechanical 2.5, eLine Advanced Electronic 10 (SC\/MC), ePet Electronic 10 (SC\/MC), ProLine Electronic 10; \u003cstrong\u003eRainin\u003c\/strong\u003e Pipet-Plus Latch Mode 2, Pipet-Plus Latch Mode 10, EDP 10; \u003cstrong\u003eLabnet\u003c\/strong\u003e Labpette 2, Labpette 10 (SC\/MC); \u003cstrong\u003eSocorex\u003c\/strong\u003e Acura 2, Acura 10 (SC\/MC).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e200 µL\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"tc-fit-n\"\u003e43 models, 15 with multichannel fit\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eEppendorf\u003c\/strong\u003e Reference 20, Reference 100, Reference 200, Research 20, Research 100 (SC\/MC), Research 200, Research Pro 300, Research Plus 200, Research Plus 300 (MC); \u003cstrong\u003eGilson\u003c\/strong\u003e Pipetman 20, Pipetman 100, Pipetman 200, Pipetman Neo 100, Pipetman Neo 200, Pipetman Ultra 100; \u003cstrong\u003eSartorius\u003c\/strong\u003e mLine 20, mLine 100 (SC\/MC), mLine 200, mLine 300 (MC), ProLine 20, ProLine 100 (SC\/MC), ProLine 200, ProLine 300 (MC), ProLine Mechanical 50 (MC), eLine Advanced Electronic 120 (SC\/MC), ePet Electronic 100, ePet Electronic 250 (MC), ProLine Electronic 100 (SC\/MC), ProLine Electronic 250; \u003cstrong\u003eRainin\u003c\/strong\u003e Pipet-Plus Latch Mode 20, Pipet-Plus Latch Mode 100, EDP 20, EDP 25, EDP 100, EDP 200; \u003cstrong\u003eLabnet\u003c\/strong\u003e Labpette 20, Labpette 50 (MC), Labpette 200 (SC\/MC), Labpette 300 (MC); \u003cstrong\u003eSocorex\u003c\/strong\u003e Acura 20, Acura 50 (SC\/MC), Acura 100, Acura 200 (SC\/MC).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e1250 µL\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"tc-fit-n\"\u003e14 models, 0 with multichannel fit\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eEppendorf\u003c\/strong\u003e Reference 1000, Research 1000, Research Pro 1000, Research Plus 1000; \u003cstrong\u003eGilson\u003c\/strong\u003e Pipetman 1000, Pipetman Neo 1000; \u003cstrong\u003eSartorius\u003c\/strong\u003e mLine 1000, ProLine 1000, eLine Advanced Electronic 1000, ePet Electronic 1000, ProLine Electronic 1000; \u003cstrong\u003eRainin\u003c\/strong\u003e EDP 1000; \u003cstrong\u003eLabnet\u003c\/strong\u003e Labpette 1000; \u003cstrong\u003eSocorex\u003c\/strong\u003e Acura 1000.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eCalibration after switching tips\u003c\/h3\u003e\n\u003cp\u003eA pipette is calibrated as a system: instrument, tip and technique together. ISO 8655-2:2022 sets maximum permissible errors for pipettes complete with their tips, and ISO 8655-6:2022 scopes the gravimetric reference procedure to the whole assembly including the disposable tip, so a tip change can shift delivered volume. If your work runs to a defined tolerance, verify gravimetrically after switching, ten replicates at the low end and ten at the high end of the range, the same way you would after a service.\u003c\/p\u003e\n\u003ch3\u003eMultichannel use\u003c\/h3\u003e\n\u003cp\u003eMultichannel fit is a separate question from single-channel fit: the tips must seat evenly across every channel at once, and ISO 8655-2:2022 carries multichannel-specific tip tolerances with no single-channel equivalent. Load a full row on your multichannel, look down the line for uneven seating, and run a dye or water check across a plate before committing to a case.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePIPETMAN is a trademark of Gilson, Inc. Research, Reference and Research Plus are trademarks of Eppendorf SE. Rainin, LTS and EDP are trademarks of Mettler-Toledo. mLine, ProLine, eLine and ePet are trademarks of Sartorius. ClipTip and Finnpipette are trademarks of Thermo Fisher Scientific. GripTip is a trademark of INTEGRA Biosciences. Innovative Bioscience is not affiliated with or endorsed by any pipette manufacturer named here. Fitment reviewed 2026-08-30 against the manufacturer's published chart.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eHigh-volume labs, routine pipetting, sustainability-focused workflows, and any laboratory seeking to reduce tip-related plastic waste without compromising quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed a quote, COA, or bulk pricing?\u003c\/strong\u003e Contact our team or request a quote directly from this page.\u003c\/p\u003e","brand":"Sorenson Bioscience","offers":[{"title":"10 µL (3,840\/cs)","offer_id":45524374093847,"sku":"fap1789682318204","price":91.5,"currency_code":"USD","in_stock":true},{"title":"200 µL (3,840\/cs)","offer_id":45524374126615,"sku":"ijf1789682318205","price":118.95,"currency_code":"USD","in_stock":true},{"title":"1250 µL (3,072\/cs)","offer_id":45524374159383,"sku":"nmb1789682318206","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0799\/5496\/8599\/files\/universal-reload-pipette-tips_1.jpg?v=1789682329","url":"https:\/\/anklestabclad.shop\/products\/universal-reload-pipette-tips","provider":"My Store","version":"1.0","type":"link"}